Manufacturer                             EATON'S BUSSMANN

 

Inventory Status                        In Stock

 

Ship from                                   China

 

Transportation method             SF Express

制造商零件编号:

FRS-R-60 双指示延时慢速RK5型熔断器

FRS-R
系列:FRS-R系列,双指示延时慢速RK5型熔断器电压:- 600Vac@ @ @ @ @ - 300Vdc (1/10 to 30A @ 65-600A)@ @ @ @ @ - 250Vdc (35-60A)电流:1⁄10-600A分段容量:200kA RMS Sym.认证:CE @UL CSA@

YOUR PRICE 

In Stock

¥ 0.00

More available in 6-8 weeks

加入购物车
  •    FRS-R 系列产品型录

       FRS-R 系列产品型录

       FRS-R 系列产品型录

     

    Advanced Protection Energy Efficient 600Vac/300Vdc, 1/10-600A, Dual Element, Time-Delay Fuses

    Energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings (see data sheets).

    Time-delay – 10 second (minimum) at 500% of rated current.

    Fusetron fuses are on average 23% more energy efficient than the next leading brand.*


     

    Fusetron™ 600 V Class RK5,

    FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses

     

    Catalog symbol:

            FRS-R-(amp) (non-indicating)

            FRS-R-(amp)ID (indicating)

     

    Description:

            Advanced protection, energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings

            Time-delay – 10 second (minimum) at 500% of rated current

     

    Specifications:

    Ratings

            Volts

            600 Vac, 300 Vdc (1/10-30 A)

            600 Vac, 250 Vdc (35-60 A)

            Amps — 1/10-60 A

            Interrupting rating

            200 kA Vac RMS Sym

            20 kA Vdc

     

    Agency information:

            CE, UL® Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273

            CSA® Certified, C22.2 No. 248.12, Class 1422-02, File 53787

            CE

     

    Features:

            Dual-element feature provides the best time-delay performance, allowing closer sizing and superior protection of motors and transformers

            Closer sizing allows for smaller fuses and less costly switches

            Class RK5 fuses with a 200 kA interrupting rating for use in a broad range of applications

            Provides motor overload, ground fault, and short-circuit protection

            Helps protect motors against burnout from overloads and single-phasing when sized properly

            Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection

            Offers a 10-second time delay at 5 times the rated current

            The time-delay feature makes it possible to use fuse amp ratings that are much smaller than those of non-time delay fuses. Considerable cost savings occur by permitting the use of smaller size switches, panels, and fuses themselves.

            Provides current limitation to help protect downstream components from high fault currents.

            Gives motor running back-up protection to motors without extra costs.

     

     

     

     

    Fusetron™ 600V Class RK5

    FRS-R — 600 Vac/300 Vdc, 65-600 A, dual element, time-delay fuses

     

    Catalog symbol:

            FRS-R-(amp)

     

    Description:

    Advanced protection, energy efficient Class RK5 dual element, current-limiting, time-delay fuses. Time-delay – 10 seconds (minimum) at 500% of rated current.

     

    Specifications:

    Ratings

            Volts — 600Vac, 300Vdc

            Amps — 65-600A

            Interrupting rating

            200 kA Vac RMS Sym

            20 kA Vdc

     

    Agency information

            UL® Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273

            CSA® Certified, C22.2 No. 248.12, Class 1422-02, File 53787

            CE

     

    Features:

            Provides motor overload, ground fault and short-circuit protection. When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amps to give maximum overcurrent protection

            The time-delay feature makes it possible to use fuse amp ratings which are much smaller than those of non-time delay fuses. Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves

            Provides a good degree of short-circuit protection (greater current-limitation) to help protect downstream components from high fault currents

            Gives motor running back-up protection to motors without extra cost

            Helps protect motors against burnout from overloads and single-phasing when sized properly

            Simplifies and improves blackout prevention (selective coordination ratios)

            Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high-performance, short-circuit and overload protection

     

     

     Catalog Numbers (Amps)

      FRS-R-1⁄10

        FRS-R-2

        FRS-R-10*

        FRS-R-100

      FRS-R-1⁄8

        FRS-R-2-1⁄4

        FRS-R-12*

        FRS-R-110

      FRS-R-15⁄100

        FRS-R-2-1⁄2

        FRS-R-15*

        FRS-R-125

      FRS-R-2⁄10

        FRS-R-2-8⁄10

        FRS-R-17-1⁄2*

        FRS-R-150

      FRS-R-1⁄4

        FRS-R-3

        FRS-R-20*

        FRS-R-175

      FRS-R-3⁄10

    FRS-R-3-2⁄10

        FRS-R-25*

        FRS-R-200

      FRS-R-4⁄10

        FRS-R-3-1⁄2

        FRS-R-30*

        FRS-R-225

      FRS-R-1⁄2

        FRS-R-4

        FRS-R-35*

        FRS-R-250

      FRS-R-6⁄10

        FRS-R-4-1⁄2

        FRS-R-40*

        FRS-R-300

      FRS-R-8⁄10

        FRS-R-5

        FRS-R-45*

        FRS-R-350

      FRS-R-1

        FRS-R-5-6⁄10

        FRS-R-50*

        FRS-R-400

      FRS-R-1-1⁄8

        FRS-R-6*

        FRS-R-60*

        FRS-R-450

      FRS-R-1-1⁄4

        FRS-R-6-1⁄4*

      FRS-R-65

        FRS-R-500

      FRS-R-1-4⁄10

        FRS-R-7*

      FRS-R-70

        FRS-R-600

      FRS-R-1-1⁄2

        FRS-R-7-1⁄2*

      FRS-R-75

     

      FRS-R-1-6⁄10

        FRS-R-8*

      FRS-R-80

     

      FRS-R-18⁄10

        FRS-R-9*

      FRS-R-90

     

    For superior electrical protection, Cooper Bussmann recommends upgrading FRS-R fuse applications to Low-Peak LPS-RK fuses. See page 29.*Available with indication. To order, place “ID” at the end of the catalog number. Example: FRS-R-7ID.